TY - JOUR
T1 - A collection input based support tensor machine for lesion malignancy classification in digital breast tomosynthesis
AU - Yang, Benjuan
AU - Wu, Yingjiang
AU - Zhou, Zhiguo
AU - Li, Shulong
AU - Qin, Genggeng
AU - Chen, Liyuan
AU - Wang, Jing
N1 - Publisher Copyright:
© 2019 Institute of Physics and Engineering in Medicine.
PY - 2019/12/5
Y1 - 2019/12/5
N2 - Digital breast tomosynthesis (DBT) with improved lesion conspicuity and characterization has been adopted in screening practice. DBT-based diagnosis strongly depends on physicians' experience, so an automatic lesion malignancy classification model using DBT could improve the consistency of diagnosis among different physicians. Tensor-based approaches that use the original imaging data as input have shown promising results for many classification tasks. However, DBT data are pseudo-3D volumetric imaging as the slice spacing of DBT is much coarser than that of the in-plane resolution. Thus, directly constructing DBT as the third-order tensor in a conventional tensor-based classifier with introducing additional information to the original DBT data along the slice-spacing dimension will lead to inconsistency across all three dimensions. To avoid such inconsistency, we introduce a collection input based support tensor machine (CISTM)-based classifier that uses the tensor collection as input for classifying lesion malignancy in DBT. In CISTM, instead of introducing the third dimension directly into the geometry construction, the third-dimension structural relationship is related by weight parameters in the decision function, which is dynamically and automatically constructed during the classifier training process and is more consistent with the pseudo-3D nature of DBT. We tested our method on a DBT dataset of 926 images among which 262 were malignant and 664 were benign. We compared our method with the latest tensor-based method, KSTM (kernelled support tensor machine), which does not consider the unique non-uniform resolution property of DBT. Experimental results illustrate that the CISTM-based classifier is effective for classifying breast lesion malignancy in DBT and that it outperforms the KSTM-based classifier.
AB - Digital breast tomosynthesis (DBT) with improved lesion conspicuity and characterization has been adopted in screening practice. DBT-based diagnosis strongly depends on physicians' experience, so an automatic lesion malignancy classification model using DBT could improve the consistency of diagnosis among different physicians. Tensor-based approaches that use the original imaging data as input have shown promising results for many classification tasks. However, DBT data are pseudo-3D volumetric imaging as the slice spacing of DBT is much coarser than that of the in-plane resolution. Thus, directly constructing DBT as the third-order tensor in a conventional tensor-based classifier with introducing additional information to the original DBT data along the slice-spacing dimension will lead to inconsistency across all three dimensions. To avoid such inconsistency, we introduce a collection input based support tensor machine (CISTM)-based classifier that uses the tensor collection as input for classifying lesion malignancy in DBT. In CISTM, instead of introducing the third dimension directly into the geometry construction, the third-dimension structural relationship is related by weight parameters in the decision function, which is dynamically and automatically constructed during the classifier training process and is more consistent with the pseudo-3D nature of DBT. We tested our method on a DBT dataset of 926 images among which 262 were malignant and 664 were benign. We compared our method with the latest tensor-based method, KSTM (kernelled support tensor machine), which does not consider the unique non-uniform resolution property of DBT. Experimental results illustrate that the CISTM-based classifier is effective for classifying breast lesion malignancy in DBT and that it outperforms the KSTM-based classifier.
UR - http://www.scopus.com/inward/record.url?scp=85076198130&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85076198130&partnerID=8YFLogxK
U2 - 10.1088/1361-6560/ab553d
DO - 10.1088/1361-6560/ab553d
M3 - Article
C2 - 31698349
AN - SCOPUS:85076198130
SN - 0031-9155
VL - 64
JO - Physics in medicine and biology
JF - Physics in medicine and biology
IS - 23
M1 - 235007